DieHard 71341 Manuel du propriétaire Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 10
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
10
ERROR
CODE
DESCRIPTION REASON/SOLUTION
F06
The charger detected that the
battery may be getting too hot
(thermal runaway).
The charger automatically shuts the current off if
it detects the battery may be getting too hot. Have
the battery checked or replaced.
If you get an error code, check the connections and settings and/or replace the battery.
Troubleshooting
PROBLEM POSSIBLE CAUSE REASON/SOLUTION
Charger will not turn
on when properly
connected.
AC outlet is dead.
Poor electrical connection.
Battery is defective.
Check for open fuse or circuit
breaker supplying AC outlet.
Check power cord and extension
cord for loose tting plug.
Have the battery checked.
Three LEDs come on for
2 seconds, then turn off.
The charger is plugged into an
AC outlet.
No problem; this is normal.
Engine start does
not work.
Drawing more than 250 amps.
Failure to wait 3 minutes (180
seconds) between cranks.
The charger may be
overheated.
Battery may be severely
discharged.
Crank time varies with the
amount of current drawn. If
cranking draws more than 250
amps, crank time may be less
than 5 seconds.
When the Engine Start LED
blinks, wait 3 minutes of rest time
before the next crank.
The thermal protector may have
tripped and needs a little longer
to reset. Make sure the charger
vents are not blocked. Wait and
try again.
On a severely discharged battery,
use the 40A Boost rate for 10 to 15
minutes, to help assist in cranking.
The Boost LED is
ashing.
The charger was left in Boost
mode for an extended period
of time.
The Boost LED will ash for 30
minutes, then go off, and the
Charging LED will light, indicating
the charger has switched to
Charging mode.
14. BEFORE RETURNING FOR REPAIRS
•When a charging problem arises, make
certain that the battery is capable of
accepting a normal charge. Double check
all connections, the AC outlet for a full
120 volts, the charger clamps for correct
polarity and the quality of the connections
from the cables to the clamps and from
the clamps to the battery system. The
clamps must be clean.
•When an UNKNOWN OPERATING
PROBLEM arises, please read the
complete manual and call the customer
service number for information. This will
usually eliminate the need for return.
If the above solutions do not eliminate the problem,
or for information about troubleshooting or replacement parts,
call toll-free from anywhere in the U.S.A.
1-800-732-7764
7:00 am to 5:00 pm CT, Monday through Friday
Vue de la page 9
1 2 3 4 5 6 7 8 9 10

Commentaires sur ces manuels

Pas de commentaire